47
E55
OUT OF SCREEN
• The calibration camera’s position
has shifted after its position and
zoom were adjusted.
• Return to the main menu, and
perform calibration again.
E56
RE-FOCUS
• The calibration points on the
screen are not detected, even after
the focus is fine-tuned.
E61
CAL:(Calibration) CENTER OVER
• The center positions of the two
projectors are outside the scope of
electronic calibration.
• Reset the distortion correction
values. (Refer to the digital cinema
dual system’s Installation Manual.)
• Return to the main menu, and
perform calibration again so that
the centers of the to projectors are
as close to each other as possible.
E62
UNKNOWN SIGNAL
• The image used for adjustment is
not detected.
• Verify that the adjustment CPL is
being played back.
E63
NO CENTER POINT
• An error had occurred with the
image used for adjustment.
• The calibration camera cannot
detect the image.
• Return to the main menu, and
perform calibration again.
E64
CAMERA SHAKE
• The calibration camera shifted
during calibration.
E65
OUT OF RANGE
• An abnormal test pattern is
displayed.
• The projectors cannot be
controlled.
• Check the installation environment
of the calibration camera. (Refer to
the digital cinema dual system’s
Installation Manual.)
• Return to the main menu, and
perform calibration again.
Error code Category
Error message
Possible cause
Solution