140
Operation Warnings
Ch
apt
er 8
Mai
n
te
nan
c
e
Operation/error messages
An operation or error message is displayed in the
operation/error message display area
in the
viewfinder.
1) In this case, position the tape at the point where you want to start the
recording manually.
2) Contact your nearest Sony dealer.
3) For detailed information on how to unload the cassette manually, see
“Unloading a cassette manually (manual eject)” on page 36
.
4) For detailed information on the full top sensor, refer to the Maintenance
Manual.
Operation/error
message
Meaning
AUTO INTERVAL
**M**S
Indicates the camera is in the Auto
Interval Rec mode. **M**S indicates
the shooting interval.
MANU INTERVAL
*FRAME
Indicates the camera is in the single
shot mode of the Manual Interval Rec
mode. *FRAME indicates the number
of frames.
INTERVAL **S(M/
H)*FRAME
Indicates the camera is in the
consecutive mode of the Manual
Interval Rec mode. **S(M/H) indicates
the trigger interval and *FRAME
indicates the number of frames.
LOW LIGHT
Appears, if set to ON on the menu, to
indicate the subject illumination is
inadequate.
TAPE REC INH.
Appears when recording on a write-
protected cassette.
Retake Search
Failed
Appears when the camcorder fails to
position the tape at recording starting
point when recording using the RE-
TAKE function.
1)
Humid Disturbed
INT REC
Appears when there are portions
where recording has failed due to
condensation while shooting pictures
at intervals (using the interval rec
function).
INVALID
OPERATION !
Appears when:
• there is only one recorded cut when
recording using the RE-TAKE
function.
• the recorded cuts are less than 3
sec. when recording using the RE-
TAKE function.
• the RE-TAKE function was denied
for some reason, e.g. as Picture
Cache was on.
• when you execute the RE-TAKE
operation before the recording
pause operation has completed.
ON-BOARD
BATTERY EMPTY
Appears when the backup battery for
the internal clock has been used up.
2)
Power OFF &
Manual Eject
Indicates the failure in the tape
transport mechanism (the tape is
slacked). Turn off the power, and then
unload the cassette manually.
3)
Full Top Sensor
Error
Indicates that the trouble of the full top
sensor
4)
is detected. Replace the full
top sensor
2)
.
VTR ERROR!
POWER OFF
b
ON
Indicates that the trouble of the MCU
for controlling the VTR section is
detected.
2)
REC Current ARM
Indicates that the trouble of the power
supply system for the drum recorder is
detected. Recording continues but
may not be substandard.
2)