2-8
GY-2120WD/WS
2-2. Periodic check
Item
Hours
Inspetion Hours (h)
Replacement Parts
Procedure
Meter 1500 3000 4500 6000
Part Name
Parts No.
Q’ty
Drum Block
Upper Drum
*
1
2
–
R
–
↓
UPPER DRUM ASSY (DDR-55-R)
A-8312-567-
1
Refer to Section 3-3-1.
Brush/Slip Ring
2
–
R
–
↓
BRUSH SR4 ASSY (RP)
A-8312-151-
1
Refer to Section 3-3-2.
Drum
*
1
2
–
–
–
R
DRUM ASSY (DDH-55A-R)
A-8312-566-
1
Refer to Section 3-3-3.
Cleaners
Cleaning Roller
*
2
2
Replace when used
↓
V CLEANING ROLLER ASSY
X-3167-281-
1
Refer to Section 3-3-4.
1,000H.
CR SPACER
3-182-765-
1
Rotary Head Cleaner
2
–
–
–
R
VIDEO HEAD CLEANER ASSY
A-8267-398-
1
Refer to Section 3-3-4.
CTL/TC Head Cleaner
*
2
2
–
R
–
R
CL ARM ASSY
X-3167-053-
1
Refer to Section 3-5-1.
Tape Running System
Pinch Roller
*
2
2
–
R
–
R
GROOVED PINCH ARM ASSY
X-3604-682-
1
Refer to Section 3-5-2.
CTL/TC Head
2
–
–
–
R
AT HEAD ASSY
A-8318-771-
1
Refer to Section 3-6-1.
Capstan Motor
2
–
–
–
R
DC MOTOR
1-698-179-
1
Refer to Section 3-6-2.
Driving System
Pinch Solenoid
2
–
–
–
R
PINCH PRESS ASSY
A-6749-117-
1
Refer to Section 3-6-3.
Reel Motor
2
–
R
–
R
RS TABLE (T) BLOCK ASSY
A-8267-702-
1
Refer to Section 3-2-3.
RS TABLE (S) BLOCK ASSY
A-8267-703-
1
Others
Air Filter
*
1
1
–
–
–
R
FILTER ASSY
A-8007-311-
1
Refer to Section 3-7-2.
Fan Motor
1
Replace when used 50,000H.
FAN MOTOR
1-698-779-
1
Refer to Section 3-7-1.
*
1: Do not put this unit in a place subject to high humidity or excessive dust. This may shorten the life of these parts. Therefore, it is recommended to use this
unit in an air-conditioned and dust-free environment and store the tape at ordinary temperature and humidity.
*
2 : The life of these parts may be shortened depending on the operating condition of this unit or the operating environment.
For parts that are used for special application in which the cassette tape in ejected and inserted 50 times or more a day, the
parts blow are added as the parts to be replaced.
Item
Hours
Inspetion Hours (h)
Replacement Parts
Procedure
Meter 1500 3000 4500 6000
Part Name
Parts No.
Q’ty
Tape Running System
S Tension Regulator
3
Replace when used 200,000 times.
TENSION REGULATOR ASSY
A-8277-408-
1
Refer to Section 3-4-1.
T Tension Regulator
3
Replace when used 200,000 times.
T-TEN ASSY
A-8273-996-
1
Refer to Section 3-6-5.
T Drawer
3
Replace when used 200,000 times.
T DRAWER ASSY
A-8274-876-
1
Refer to Section 3-6-6.
Driving System
Threading Motor
3
Replace when used 200,000 times.
GEAR BOX ASSY
A-8273-997-
1
Refer to Section 3-6-4.
Threading Ring
3
Replace when used 200,000 times.
THREADING RING ASSY
A-8267-395-
1
Refer to Section 3-5-3.
Pinch Arm Guard
3
Replace when used 200,000 times.
PINCH ARM GUARD
3-180-853-
1
CL Guide Rail
3
Replace when used 200,000 times.
CL GUIDE RAIL
3-180-874-
1
Brake Solenoid
3
Replace when used 200,000 times.
TABLE (T) BLOCK ASSY
A-8267-702-
1
Refer to Section 3-2-3.
TABLE (S) BLOCK ASSY
A-8267-703-
1
Other
Cassette Compartment Assy
3
Replace when used 200,000 times.
CASSETTE COMPARTMENT ASSY
A-8267-863-
1
Refer to Section 1-1-2.
Содержание GY-2120WD
Страница 10: ......
Страница 27: ...1 17 GY 2120WD WS 1 6 Fixture and Measuring Equipment for Adjustment 1 2 3 4 5 6 7 8 9 0 18 10 d l l d d ...
Страница 224: ......
Страница 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Страница 457: ...7 23 GY 2120WD WS Printed Circuit Board Bottom Side Block 902 902 901 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 ...
Страница 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Страница 476: ......
Страница 482: ......