6-93
GY-2120WD/WS
RF07
RF NV-RAM Save (RF adjustment command)
RF08
RF NV-RAM Load (RF adjustment command)
RF09
RF Initial Data Set (RF adjustment command)
Function:
RF07: Saves the adjustment data of RF electronic VR in an RF NV-RAM
(Non-volatile RAM).
n
Once the RF07 command is executed, the RF adjustment data cannot be returned to the state
before adjustment.
RF08: Sets the adjustment data of an RF NV-RAM to RF electronic VR.
RF09: Sets the initial value of adjustment data to RF electronic VR.
Operation:
(1) Enter command.
After the title, the following message is then displayed on the screen.
Are you ready (y/n)?
*
To stop the execution of adjustment, press the N key.
(2) Press the Y key to initiate data transmission.
(3) After transmission is completed, messages below are displayed on the screen.
“Data Saved” for RF07 command
“Data Loaded” for RF08 command
“Data Set” for RF09 command
Examples:
6-2. Description of Commands
.
For RF07
------>rf07
RF Adjust [NV-RAM Control]
RF NV-RAM Save
Are you ready (y/n)? Yes
Saving....OK
Data Saved
------>_
.
For RF09
------>rf09
RF Adjust [Auto Adjust]
RF Initial Data Set
Are you ready (y/n)? Yes
Setting....OK
Data Set
------>_
.
For RF08
------>rf08
RF Adjust [NV-RAM Control]
RF NV-RAM Load
Are you ready (y/n)? Yes
Loading....OK
Data Loaded
------>_
Содержание GY-2120WD
Страница 10: ......
Страница 27: ...1 17 GY 2120WD WS 1 6 Fixture and Measuring Equipment for Adjustment 1 2 3 4 5 6 7 8 9 0 18 10 d l l d d ...
Страница 224: ......
Страница 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Страница 457: ...7 23 GY 2120WD WS Printed Circuit Board Bottom Side Block 902 902 901 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 ...
Страница 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Страница 476: ......
Страница 482: ......