![Sony GY-2120WD Скачать руководство пользователя страница 259](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991259.webp)
6-35
GY-2120WD/WS
6-2. Command Description
5
Log parameters
Log Parameter
Contents
1’st Vol [XXXXXX-YYYYYY]
First volume range (Unit is ID)
ABN [XXXXXXXX]
Block number managed by DTF displayed in HEX
Address [XXXXXXXX]
ID number in the bank with error
Bank [XXXXX]
Bank number with error
Block [XXXX]
Block size value
Bod [XXXXXX]
Top of data of mounted volume. Unit is ID.
Bop [XXXXXX]
Top of the mounted volume. Unit is ID.
BS [XXXXXX]
Number of bad spots in the volume
C2ID [XXXXXX]
Position at which the error occurred. Unit is ID.
Cause1 [XX]
Internal I/O status of GY-2120 or error number of GY-2120
*
Cause2 [XX]
Internal I/O status in GY-2120
When
*
“Drive Power Error!!, “Drive System Error!!”...Always 0
Cmnd [XXXXXXXX]
Error code from the SYS side CPU
Command [X]
Maintenance mode command
Derr [XXXXXXXX]
SYS side error code
DIT#1 [XXXXXX]
Top position of first volume. Unit is ID.
EOD [XXXXXX]
EOD position in the volume. Unit is ID.
Eop [XXXXXX]
Last position of mounted volume. Unit is ID.
FActMode [XXXXXXXX]
GY-2120 internal mode
FILE [XXXXXX]
Number of filemarks or set marks in the volume
fLoad [XXXXXXXX]
Internal load state of GY-2120
HOST [X]
Host SCSI ID
ID [XXXXXXX]
ID number in the bank read
Inhi [XXXX]
Recording-prohibited mode value
lEot [XXXXXX]
Last position of the tape. Unit is ID.
len [XXXXXXXX]
Block data length
Length [XXXXXXXX]
Memory address in the ID
Leot [XXXXXX]
EOT position of the tape. Unit is ID.
NumRecv [XXXXX]
Number of faults detected
Mode [XXXX]
Buffer mode value
OWC [XXXXXXXX]
Overwrite count for the volume
OWN [X]
GY-2120 SCSI ID
Rsv [XXXXXXXX]
(Always 0)
Scsi [XX]
SCSI command during error or execution
ScsiCmd [XX]
SCSI command executed
sync : X
Sync mode
Tape [XXXXXXXX]
Unique number of the tape
TAR (XXXXXXXX)[Y]
Targetted model name and SCSI ID
Tbl [XXXXXXX]
Block table managed by DTF. Displayed in HEX.
TopID [XXXXXX]
Position inside the bank with the error. Unit is ID.
VolCnt [XXX]
Number of volumes in the tape
VolNo. [XXX]
Targetted volume number
wide : X
Wide mode
Содержание GY-2120WD
Страница 10: ......
Страница 27: ...1 17 GY 2120WD WS 1 6 Fixture and Measuring Equipment for Adjustment 1 2 3 4 5 6 7 8 9 0 18 10 d l l d d ...
Страница 224: ......
Страница 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Страница 457: ...7 23 GY 2120WD WS Printed Circuit Board Bottom Side Block 902 902 901 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 PWH3 x 8 ...
Страница 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Страница 476: ......
Страница 482: ......