14(E)
Indications in the LCD Panel
The following indications may appear either during or
after the operation described on the previous pages.
Operation
Indication
Power on
DMS-B9
POWER indicator lights
Rev. XXX.XX
Revision indication
SCSI ID: X ZZ
SCSI ID indication
(X: SCSI ID for the DMS-B9, ZZ: Type of
the SCSI interface of the DMS-B9; WD for
Wide Differential or WS for Wide Single-
ended)
Opening the
>Aborting..
door key switch
Opening the
>DOOR OPEN!
DOOR indicator flashes
front door
Closing the
>DOOR CLOSED DOOR indicator lights
front door
Closing the door >Initialize..
BUSY indicator flashes
key switch
When initializa-
>IN USE
POWER indicator only
tion completed
lights
During SCSI
>IN USE
I/O indicator lights
command
execution
During elevator/ >IN USE
BUSY indicator lights
hand movement
While the unit is operating normally, the following
indications may appear.
Indication
Significance
>Aborting..
The elevator is being parked at the
bottom, ready for the door to open.
>DOOR OPEN!
The door is open.
>DOOR CLOSED
The door is closed.
>Initialize..
The elevator is being initialized.
>IN USE
The unit is ready for use.
>MediaLocked
The door key is switched to the “Open”
position, but unlocking is disabled with
the PREVENT ALLOW MEDIUM
REMOVAL command from the SCSI
set to Prevent.
>SCSI abort..
The host sends the SCSI bus reset by
turning the power ON.
If a fault is detected while the unit is operating, the
following indications may appear.
Indication
Significance
>ERROR:XXXXXX An error has occurred, stopping
operation.
(For details of the error
codes, see page 30(E).)
>Init CPU I/F
An SCSI interface error has occurred,
for example because the SCSI
interface is not supplied with
termination power.
––
∗
X
A warning error has occurred without
stopping operation.
(For details of the
warning, see page 31(E).)
X indicates an alphabet or digit.
Removing or Replacing a
Cassette
1
Turn the door key switch to the “Open” position.
The front door opens.
2
Press down the two retainer hooks.
The cassette springs out.
3
Insert a new cassette as required.
Operation