background image

Operating instructions  

Ultrasonic diffuse-reflection sensor 

without IO-Link

UIT509 

UIT512 

UIT515

11487721 / 00 

 

08 / 2018

UK

UK

Содержание UIT509

Страница 1: ...Operating instructions Ultrasonic diffuse reflection sensor without IO Link UIT509 UIT512 UIT515 11487721 00 08 2018 UK UK ...

Страница 2: ...ut any restrictions Only use the product for its intended purpose 3 Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up ope...

Страница 3: ...eet No object detection in the dead zone For units with metal housing according to UL 508 Observe a minimum distance of 12 7 mm between the sensor and non insulated live parts For further information please refer to www ifm com General information about installation and operation 5 Electrical connection Disconnect power Connect unit depending on the type selected BK black BN brown BU blue WH white...

Страница 4: ...Press the teach button for 1 s Yellow status LEDs 1 2 flash 2 5 Hz P1 setting is completed Position the object in P2 Fig 1 or 2 Press the teach button for 1 s Yellow status LEDs 1 2 flash briefly 4 Hz P2 setting is completed 6 1 3 Invert output response Press the teach button for 6 s Yellow status LEDs 1 2 flash 10 Hz Yellow status LEDs 1 2 flash briefly 4 Hz Output function is inverted 6 1 4 Rest...

Страница 5: ...s Complementary switching outputs 1 1 B P2 P1 1 0 0 3 4 2 B P1 P2 2 1 0 1 0 1 3 4 Inverted switching outputs Inverted switching outputs 1 1 B P2 P1 1 0 0 2 3 4 1 1 B P1 P2 1 0 0 2 3 4 1 output response 2 distance to the object 3 OUT1 switching output 4 OUT2 switching output B blind zone P taught position T teach button Technical data and further information at www ifm com ...

Отзывы: