5-34
3. VCO Adjustment (PD-117/118 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
8
of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
A2 (NTSC model)
A2, A3 (PAL model)
Specified Value
f=15734 ± 30 Hz (NTSC model)
f=15625 ± 30 Hz (PAL model)
Note 1:
NTSC model: DCR-TRV320/TRV320P/TRV520/
TRV520P/TRV525/TRV720
PAL model: DCR-TRV320E/TRV420E/TRV520E/
TRV620E/TRV720E
Adjusting method (NTSC model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A2, change the data and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Adjusting method (PAL model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A2, change the data, and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of adjustment remote commander.
4)
Read the adjustment data of step 2), and this data is named
D
A2
.
5)
Convert D
A2
to decimal notation, and obtain D
A2
’.
(Refer to Table 5-4-1 “Hexdecimal-decimal conversion table”
of “5-4. Service Mode”)
6)
Calculate D
A3
’ using following equations (decimal calculation),
convert it to a hexdecimal number, and obtain D
A3
.
2.5 LCD TYPE C 61 k model/
2.5 LCD TYPE S 61 k model:
D
A3
’ = D
A2
’ – 16
2.5 LCD TYPE S 123 k model/
3 LCD TYPE S model/
4 LCD TYPE C model/
4 LCD TYPE S model:
D
A3
’ = D
A2
’ – 23
3.5 LCD TYPE C model/
3.5 LCD TYPE S model:
D
A3
’ = D
A2
’ – 4
Note 2:
If D
A3
’ < 0, then D
A3
= “00”
7)
Select page: D, address: A3, set data D
A3
, and then press the
PAUSE button of adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
2. LCD Initial Data Input (2)
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
A0 to AA, AC to B1
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note 1:
To write in the non-volatile memory (EEPROM),
press the PAUSE button of the adjustment remote
commander each time to set the data.
3)
Select page: 0, address:01, and set data: 00.
Note 2:
*
mark data
Address
Data
Remark
TYPE S
TYPE C
A0
*
*
Fixed data (Note 3)
A1
*
*
A2
80
80
VCO adj.
A3
70
70
VCO adj. (PAL model)
Fixed data (NTSC model)
A4
80
80
V-COM adj.
A5
30
20
RGB AMP adj.
A6
00
00
Fixed data
A7
C0
80
COM AMP adj.
A8
80
80
White balance adj.
A9
80
80
AA
50
30
Contrast adj.
AC
*
*
Fixed data (Note 3)
AD
*
*
AE
9F
9F
Fixed data
AF
1F
1F
B0
FC
FC
B1
FF
FF
Data
Address
TYPE S
TYPE C
2.5
2.5
61 k 123 k
3
3.5
4
61 k
3.5
4
A0
78
78
6C
70
7D
78
70
7D
A1
95
95
85
8D
A6
95
8D
A6
AC
14
33
73
53
33
0A
55
33
AD
14
14
14
14
14
0E
13
13
Содержание D8 Digital Handycam DCR-TRV420E
Страница 104: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 69 4 70 USER CONTROL CF 69 ...
Страница 108: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 77 4 78 USER CONTROL CF 70 ...
Страница 110: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 81 4 82 USER CONTROL CF 72 ...
Страница 252: ... 321 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...