5-20
5. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the CCD
imager.
If deviated, the screen center will be shifted when the lens is zoomed
from TELE end to WIDE end.
Subject
Siemens Star (PTB-450)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
60
Note
: “Flange Back Adjustment” must be already finished.
Switch setting:
1) NIGHT SHOT ................................................................... OFF
2) DIGITAL ZOOM (Menu display) ..................................... OFF
3) STEADY SHOT (Menu display) ...................................... OFF
Preparation for adjustment:
1) Play a monoscope portion of the System Check tape (WR5-
5ND(NTSC) or WR5-5CD(PAL)).
2) Stick the optical axis deviation specification frame to the monitor
screen so that the center of monoscope coincides with the center
of specification frame.
3) Select the CAMERA mode.
Adjustment method:
1) Select page:0, address:01, and set data:01.
2) Select page:F, address:60, and set data:00, then press the PAUSE
button on the adjusting remote commander.
3) Place the Siemens Star at 2m position away from the lens.
4) Shoot the Siemens Star with the zoom at TELE end.
5) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specification
frame.
6) Shoot the Siemens Star with the zoom at WIDE end.
7) Check on the monitor TV which area the center of Siemens
Star exists of the optical axis deviation specification frame.
At this time, measure the amount of deviation “L1” (distance
from the center of Siemens Star to the center of optical axis
deviation specification frame).
8) From the following table, read correction data according to the
area.
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
Fig. 5-1-9
Area
1
2
3
4
5
6
7
8
Deviation Phase
22.6
°
to 67.5
°
67.6
°
to 112.5
°
112.6
°
to 157.5
°
157.6
°
to 202.5
°
202.6
°
to 247.5
°
247.6
°
to 292.5
°
292.6
°
to 337.5
°
337.6
°
to 22.5
°
Correction Data
01
02
03
04
05
06
07
08
9)
Select page:F, address:60, and set correction data, then press
the PAUSE button on the adjusting remote commander.
10) Shoot the Siemens Star with the zoom at TELE end.
11) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specification
frame.
12) Shoot the Siemens Star with the zoom at WIDE end.
13) Measure the amount of deviation “L2” (distance from the center
of Siemens Star to the center of optical axis deviation
specification frame).
14) Compare L1 and L2, and make sure that the L2 is smaller than
L1.
If large, select page:F, address:60, and set data:00, then press
the PAUSE button on the adjusting remote commander.
Processing after completion of adjustment:
1)
Select page:0, address:01, and set data:00.
Содержание D8 Digital Handycam DCR-TRV420E
Страница 104: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 69 4 70 USER CONTROL CF 69 ...
Страница 108: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 77 4 78 USER CONTROL CF 70 ...
Страница 110: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 81 4 82 USER CONTROL CF 72 ...
Страница 252: ... 321 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...