– 15 –
DCR-TRV320/TRV320E/TRV320P/TRV420E/TRV520/TRV520E/TRV520P/TRV525
TRV620E/TRV720/TRV720E
A
A: PSIG signal amplitude
V
6. Black Limit Adjustment (PD-133 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
4
of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A6
Specified Value
A=8.15
±
0.08 Vp-p
7. Center Voltage Adjustment (PD-133 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
3
of CN5502 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
AB
Specified Value
A=7.00
±
0.03 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
2
0E
61
3
2
0F
Set the following data
5B (NTSC), 53 (PAL)
4
D
A6
Change the data and set the
voltage (A) to the specified value.
(The data should be “00” to “0F”)
5
D
A6
Press PAUSE button.
6
2
0E
00
7
2
0F
00
8
0
01
00
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
AB
Change the data and set the DC
voltage (A) to the specified value.
(The data should be “00” to “7F”)
3
D
AB
Press PAUSE button.
4
0
01
00
Fig. 5-3-31
Note:
NTSC model: DCR-TRV320/TRV320P
PAL model: DCR-TRV320E
Содержание D8 Digital Handycam DCR-TRV420E
Страница 104: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 69 4 70 USER CONTROL CF 69 ...
Страница 108: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 77 4 78 USER CONTROL CF 70 ...
Страница 110: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 81 4 82 USER CONTROL CF 72 ...
Страница 252: ... 321 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...