5-45
D
1
(decimal)
D
2
(decimal)
H
1
(hexadecimal)
(Service model code)
00001 to 65535
D
1
00
65536 to 131071
D
1
– 65536
00
131072 to196607
D
1
– 131072
00
196608 to 262143 D
1
– 196608
00
Page
C
Address
E8, E9, EA, EB, EC
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of 7, 8, C, D, E, F Page Data
If the 7, 8, C, D, E, F page data is erased due to some reason, perform
“1-2. INITIALIZATION OF 7, 8, C, D, E, F PAGE DATA”, of “5-
1. CAMERA SECTION ADJUSTMENT”
2. Node Unique ID No. Input
Note 1:
Perform “2-2. Input of Serial No.” if the data on page C
has been cleared and the node unique ID No. is not found.
2-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory).
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Enter the following data.
Note 2:
Each time the data is set, press the PAUSE button on the
adjusting remote commander.
Address
Data
E8
08
E9
00
EA
46
EB
01
EC
01
3)
Select page: 0, address: 01, and set data: 00.
2-2. Input of Serial No.
Write the serial No. and model code to the EEPROM (nonvolatile
memory).
In writing the serial No., a decimal number should be converted into
a hexadecimal number.
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. from the model name label, and it is assumed
to be D
1
.
Example: If serial No. is “77881”,
D
1
= 77881
3)
From Table 5-3-3, obtain D
2
and H
1
that correspond to D
1
.
Example: If D
1
= 77881,
D
2
= D
1
– 65536 = 12345
H
1
= 00
Page
C
Address
ED, EE, EF
Table 5-3-3
4)
Enter H
1
to address: ED on page: C.
Example: If H
1
= 00,
select page: C, address: ED, and set data: 00, then press the
PAUSE button.
5)
From Table 5-3-4, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
= 12345.
D
3
= 12288
6)
From Table 5-3-4, obtain a hexadecimal number that corresponds
to D
3
, and it is assumed to be H
3
.
Example: If D
3
= 12288,
H
3
= 3000
7)
Caluculate D
4
using following equations (decimal caluculation).
(0 D
4
225)
D
4
= D
2
– D
3
Example: If D
2
= 12345 and D
3
= 12288,
D
4
= 12345 – 12288 = 57
8)
Convert D
4
into a hexadecimal number to obtain H
4
. (See Table
5-4-1 “Hexadecimal - decimal conversion table” in 5-4. Service
Mode)
Example: If D
4
= 57,
H
4
= 39
9)
Enter higher two digits of H
3
to address: EE on page: C.
Example: If H
3
= 3000,
select page: C, address: EE, and set data: 30, then press the
PAUSE button.
10) Enter H
4
to address: EF on page: C.
Example: If H
4
= 39,
select page: C, address: EF, and set data: 39, then press the
PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
Ver. 1.1 2001. 01
Содержание D8 Digital Handycam DCR-TRV420E
Страница 104: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 69 4 70 USER CONTROL CF 69 ...
Страница 108: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 77 4 78 USER CONTROL CF 70 ...
Страница 110: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 81 4 82 USER CONTROL CF 72 ...
Страница 252: ... 321 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...