5-30
Address
Data
Remark
COLOR
B/W
92
80
80
VCO adj.
93
70
70
VCO adj. (PAL model)
Fixed data (NTSC model)
94
26
26
Fixed data
95
A0
A0
RGB AMP adj.
96
0F
0F
Fixed data
97
80
80
White balance adj.
(COLOR LCD EVF model)
98
80
80
Fixed data
(B/W LCD EVF model)
99
30
30
Contrast adj.
9A
80
80
Fixed data
9B
90
90
9C
D0
D0
Backlight consumption
9D
10
10
current adj.
9E
10
10
9F
1F
18
Fixed data
B0
FC
FC
B2
FF
FF
2. EVF Initial Data Input (2)
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
92 to 9F, B0, B2
Note:
COLOR LCD EVF model:
DCR-TRV525/TRV620E/TRV720/TRV720E
B/W LCD EVF model:
DCR-TRV320E: AEP, UK, EE, NE, RU/TRV420E:
AEP/TRV520E: AEP
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: 0, address:01, and set data: 00.
3. VCO Adjustment (VF-141 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
qa
of CN1108 (VCO) on VC-235
board
Measuring Instrument
Frequency counter
Adjustment Page
D
Adjustment Address
92 (NTSC model)
92, 93 (PAL model)
Specified Value
f=15734 ± 30 Hz (NTSC model)
f=15625 ± 30 Hz (PAL model)
Note 1:
NTSC model: DCR-TRV320/TRV320P/TRV520/
TRV520P/TRV525/TRV720
PAL model: DCR-TRV320E/TRV420E/TRV520E/
TRV620E/TRV720E
Adjusting method (NTSC model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 92, change the data and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Adjusting method (PAL model):
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 92, change the data, and set the VCO
frequency (f) to the specified value.
3)
Press the PAUSE button of adjustment remote commander.
4)
Read the adjustment data of step 2), and this data is named
D
92
.
5)
Convert D
92
to decimal notation, and obtain D
92
’.
(Refer to Table 5-4-1 “Hexdecimal-decimal conversion table”
of “5-4. Service Mode”)
6)
Calculate D
93
’ using following equations (decimal calculation),
convert it to a hexdecimal number, and obtain D
93
.
D
93
’ = D
92
’ – 26
Note2:
If D
93
’ < 0, then D
93
= “00”
7)
Select page: D, address: 93, set data D
93
, and then press the
PAUSE button of adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
Содержание D8 Digital Handycam DCR-TRV420E
Страница 104: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 69 4 70 USER CONTROL CF 69 ...
Страница 108: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 77 4 78 USER CONTROL CF 70 ...
Страница 110: ...DCR TRV320 TRV320E TRV320P TRV420E TRV520 TRV520E TRV520P TRV525 TRV620E TRV720 TRV720E 4 81 4 82 USER CONTROL CF 72 ...
Страница 252: ... 321 FOR CAMERA OPTICAL AXIS ADJUSTMENT 0 180 90 67 5 22 5 337 5 292 5 247 5 202 5 157 5 112 5 8 4 5 7 1 6 2 3 270 ...