4 Using the PVA-600 Software
4-37
Troubleshooting PVA-600 Operation
This section describes steps to troubleshoot the operation of the PVA-600.
Troubleshooting of actual PV systems is not included.
“Disabled” message
If the message ―Disabled‖ appears in the indicator panel directly below the Measure Now
button, it means that the I-V Unit has turned itself off to protect against a condition of
over-voltage, -current, or –temperature. Click on the
[?]
icon below the indicator, and
follow the displayed instructions.
Paused
When the message ―Paused‖ appears in the indicator, this means that the I-V Unit is
temporarily disabled by the user by pressing the LED pushbutton on the I-V Unit. It is a
normal part of the operation of the Unit. In this Paused condition, PV source connections
may be changed without interrupting a measurement. The I-V Unit can be brought back
to the enabled state simply by pressing the LED pushbutton.
“No USB Wireless” message
This means that the PC cannot find the wireless USB adaptor used to communicate with
the I-V Measurement Unit. Plug the USB adaptor into an open USB port. You may need
to go to the Utilities menu, select Settings, and follow the instructions to locate the USB
adaptor. Be aware that each I-V Measurement Unit is matched with the USB adapter it
was shipped with; mixing them up will make communications impossible.
“No I-V Unit” message
In this case, the PC has found the wireless USB adaptor, but cannot communicate with
the I-V Measurement Unit. If the I-V Unit is switched off, turn it ON. If the LED is
blinking quickly, the I-V unit is trying to link. Check that the correct (matched) USB
wireless adapter is plugged into the PC, and that the PC and I-V Unit are within wireless
range of one another.
I-V Measurement Unit wireless range
Reduced wireless range can be caused by objects (especially metal) blocking the line-of-
sight from PC to I-V Unit, or by placing either the PC or the I-V Unit on top of or near
metal objects like metal roof surfaces, equipment housings and so on. The corrective
action is to clear the line-of-sight and to raise the equipment above the metal surfaces. If
these steps do not solve the problem, move the PC closer to the I-V Unit.