4 Using the PVA-600 Software
4-27
Figure 34. Irradiance and temperature communication status
b.
If the
Wireless Interface: Not Found
message appears, select
Settings
from the
Utility
menu and set up the wireless sensor USB
interface manually. Select the communications ports with the ―+‖ sign.
c.
Ensure that the
Irradiance
box blinks green every two seconds. If the box
is not blinking, you may need to move the PC closer to the sensor
transmitter location or reposition the sensor transmitter. Ensure that the
signal level increases. Refer to Setting Up the Optional PVA Sensor Kit for
setup information.
d.
Ensure that the
Temperature
box blinks green every ten seconds. If the
box is not blinking, you may need to move the PC closer to the sensor
transmitter location or reposition the sensor transmitter. Ensure that the
signal level increases. Refer to Setting Up the Optional PVA Sensor Kit for
setup information.
11.
Click on the
Measure Now
button to start a measurement. The
Ready
button will
change to
Measuring
and blink during the measurement. The red pushbutton on the
I-V Measurement Unit will blink once.
12.
Observe the measurement data in the
Predicted
and
Measured
columns in the
Table
tab as shown in Figure 35.