5 Interpreting Measured I-V Curves
5-11
3. The Slope of the Curve near Voc Does Not Match
the Prediction
An example of this type of deviation is shown in Figure 50.
Figure 50. An I-V curve in which the slope of the measured I-V curve near Voc does
not match the predicted slope
The slope of the I-V curve between Vmp and Voc is affected by the amount of series
resistance internal to the PV modules and in the array wiring. Increased resistance
reduces the steepness of the slope and decreases the fill factor.
Potential causes are summarized below, and then discussed in more detail.
Potential causes located in the array include:
PV wiring has excess resistance or is insufficiently sized
Electrical interconnections in the array are resistive
Series resistance of PV modules has increased