86
ALARM
TYPE
SOLUTION
E036
Battery temperature
out of range (only
LEAD ACID).
■
Check the presence and connections of the battery temper-
ature sensor (leadacid battery).
■
Check the battery voltage and make sure it is within the
limits allowed for operation.
■
Check that the ambient temperature is within the allowed
range.
■
Check the correct positioning of the battery and that the
installation complies with the requirements contained in this
manual.
■
Refer to the section “Electrical connections”.
■
If the problem persists, contact the technical support
service.
E037
Converter control
system fault.
■
Switch off and restart the system.
■
Refer to the sections “System switching off” and “System
switching on”
■
Should the problem persist, contact our technical support
service.
E038
Converter control
system fault.
■
Switch off and restart the system.
■
Refer to the sections “System switching off” and “System
switching on”
■
Should the problem persist, contact our technical support
service.
E001LI ÷
E0031LI
Lithium battery alarms
from battery BMS.
■
Check the connections and polarity at the BATTERY inputs
of the system.
■
Check the battery voltage and make sure it is within the
limits allowed for operation.
■
Refer to the section “Electrical connections”.
■
If the problem persists, contact the technical support
service.
W001LI ÷
W0031LI
Lithium battery
warnings from battery
BMS.
■
Check the connections and polarity at the BATTERY inputs
of the system.
■
Check the battery voltage and make sure it is within the
limits allowed for operation.
■
Refer to the section “Electrical connections”.
■
If the problem persists, contact the technical support
service.
EV001LI ÷
EV0031LI
Lithium battery mes-
saging from battery
BMS.
■
Check the connections and polarity at the BATTERY inputs
of the system.
■
Check the battery voltage and make sure it is within the
limits allowed for operation.
■
Refer to the section “Electrical connections”.
■
If the problem persists, contact the technical support
service.
Содержание 10ES-T
Страница 1: ...Instruction Manual SolarMax ES T series 5ES T 6ES T 8ES T 10ES T ...
Страница 10: ...10 3 2 Function Fig 2 Function of ES T ...
Страница 22: ...22 5 2 Electrical connection diagram ES T Fig 6 Electrical connection diagram ...
Страница 74: ...74 Fig 52 Login page The HOME page will appear Fig 53 HOME page ...