82
ALARM
TYPE
SOLUTION
E008
Internal current
leakage
■
Switch off and restart the system.
■
Refer to the sections “System switching off” and “System
switching on”
■
Should the problem persist, contact our technical support
service.
E009
NEUTRAL line wrongly
connected
■
Check that the connections of the AC input and output lines
respect the assigned polarity.
■
If the problem persists, contact the technical support
service.
E010
Failed AUTOTEST
(relevant only for CEI
0-21)
■
Check the integrity of the electrical connections.
■
Make sure that the mains voltage and frequency are within
the range allowed by the CEI 0-21 standard.
■
If the problem persists, contact the technical support
service.
E011
High grid voltage
■
Make sure that the mains voltage is within the range allowed
by local regulations.
■
Check the network impedance.
■
If the mains voltage is not within the permitted range for
reasons due to the local grid conditions, contact the grid
operator to evaluate the possibility of adapting the voltages
at the connection point or request approval for the change to
the operating limits.
■
If the mains voltage is within the allowed range, but the
alarm persists, contact the technical support service.
E012
High grid voltage
■
Make sure that the mains voltage is within the range allowed
by local regulations.
■
Check the network impedance.
■
If the mains voltage is not within the permitted range for
reasons due to the local grid conditions, contact the grid
operator to evaluate the possibility of adapting the voltages
at the connection point or request approval for the change to
the operating limits.
■
If the mains voltage is within the allowed range, but the
alarm persists, contact the technical support service.
E013
Low grid voltage
■
Make sure that the mains voltage is within the range allowed
by local regulations.
■
Check the network impedance.
■
If the mains voltage is not within the permitted range for
reasons due to the local grid conditions, contact the grid
operator to evaluate the possibility of adapting the voltages
at the connection point or request approval for the change to
the operating limits.
■
If the mains voltage is within the allowed range, but the
alarm persists, contact the technical support service.