- 50 -
- 50 -
8.6 TURBINE ROTATIONAL SPEED/ TUR-
BINE ALARM - C4
Visualization of turbine rotational speed
Select channel 4 by means of the central button
Turbine speed alarms
The minimum turbine rotational speed can be programmed.
Alarms are deactivated under 2 Km/h.
Minimum turbine speed
1-
Select canal 4.
2-
Push
longer than 5 seconds and keep it pushed.
3-
Push
for changing the digit and the value as in the
previous cases. 3800 rpm. by default
4-
Stop pushing for going back to the normal position.
Select the amount of pulses per run in the turbine (2 by de-
fault).
NOTE
: THE AMOUNT OF IMPULSES PER RUN IN THE TURBINE
IS ALWAYS 2. USE THIS PROGRAMMING MODE ONLY IN CASE
OF ERROR.
1-
PUSH THE BUTTON
FOR NEUMASEM VERSIONS OR
FOR NEUMASEM PLUS WHILE THE MONITOR IS CON-
NECTED BY MEANS OF THE REAR SWITCH, FOR ENTERING
INTO PROGRAMMING MODE 2.
2-
PUSH THE BUTTON
FOR NEUMASEM VERSIONS OR
FOR NEUMASEM PLUS FOR CALIBRATING THE CHAN-
NEL AND GO TO CHANNEL 4 (TURBINE).
3-
PUSH
FOR MODIFYING THE FLASHING DIGIT AND
KEEP PUSHING FOR MODIFYING ITS VALUE, (IT MUST AL-
WAYS BE 2).
4-
STOP PUSHING FOR GOING BACK TO THE NORMAL POSI-
TION.
8.7 DISTRIBUTOR SHAFT - C5
Select channel 5 by means of the central button
.
When the shaft stops rotating, the alarm sounds with 5 non-
stop whistles after 40 seconds. If it does not rotate, the alarm
is repeated each 30 seconds.
For deactivating the alarm, stop the engine and restart it.
This alarm is deactivated under 2 Km/h.
The shaft alarm can be deactivated by pushing the button
for more than 5 seconds in the selected channel. The
display shows «Off». In this case, the alarm is not activated
even if the engine stops and restarts.