- 34 -
- 34 -
IMPORTANT:
IN DOSAGES THAT ARE CLOSE
TO TOTAL PRODUCT QUANTITIES OF 450 Kg/Ha
(TAKE INTO ACCOUNT SEED, FERTILIZER AND
MICROGRANULATE), CHECK THAT THERE IS
NO MATERIAL BUILDUP CLOGGING THE COM-
PRESSED AIR SYSTEM. IF THERE IS, REDUCE THE
DOSE.
IMPORTANT:
AFTER COMPLETING THE FIRST
HECTARE OF WORK, CHECK THAT PRODUCT
CONSUMPTION IS AT THE DESIRED LEVEL.
6.5.2 MODELS WITH ISOBUS ELECTRICAL TRANS-
MISSION
A series of steps must be taken before performing the test:
1-
Couple the machine to the tractor in a slightly raised posi-
tion (the sowing equipment does not touch the ground).
2-
Close the dispensers’ guillotine door, removing a bolt that
fixes the door’s position (Fig. 6.41).
Fig. 6.41
Fig. 6.41
3-
Fill the product hopper.
4-
Open the cover of the Venturi injector using the two
quick-release fasteners and move the calibration control
to the test position, “
NO
” (Fig. 6.42).
Fig. 6.42
Fig. 6.42