Product individual parameters (continued)
Index
Sub
index
Access
1
Parameter
Data
type
2
Initial
value
Data
storage
3
Set value
4
Remarks
dec
hex
1410 0x0582
1
R/W
OUT
2
se
tt
in
g
oUt2
(Selection of output
mode)
U8
0
Y
0: HYS
(Hysteresis)
1: Wind
(Window comparator)
2: AC
(Accumulated output)
3: PLS
(Accumulated pulse)
4: Err (Error output)
5: oFF (Output OFF)
2
R/W
2ot
(Selection of output
type)
U8
0
Y
0: 2_P (Normal output)
1: 2_n (Reverse output)
Setting of OUT2 output normal and
reserved output
1420 0x058C
1
R/W
P_2 (n_2)
(Selection of output
set value)
S16 2000
Y
Setting range
Refer to "Settable
range list".
(Page
Setting of OUT2 output set value
(Hysteresis)
2
R/W
H_2
(Setting of OUT2
hysteresis)
U16
200
Y
Setting range
Refer to "Settable
range list".
(Page
Setting of OUT2 hysteresis
(Hysteresis)
3
R/W
P2L (n2L)
(Lower limit of
window comparator)
S16 1200
Y
Setting range
Refer to "Settable
range list".
(Page
Setting of OUT2 output set value
(Lower limit of window comparator)
4
R/W
P2H (n2H)
(Upper limit of
window comparator)
S16 2400
Y
Setting range
Refer to "Settable
range list".
(Page
Setting of OUT2 output set value
(Upper limit of window comparator)
5
R/W
WH2
(Window comparator
hysteresis)
U16
400
Y
Setting range
Refer to "Settable
range list".
(Page
Setting of OUT2 hysteresis
(Window comparator)
6
R/W
dt2
(Delay time)
U16
0
Y
Settable values
0x0000 to 0x1770
(0 to 6000)
Setting of OUT2 delay time
10 ms increment
1300 0x0514
1
R/W
OUT
1
a
c
cu
m
u
la
te
d
f
lo
w se
tt
in
g
AC1_L
(OUT1 set value (L))
S16
0
Y
Setting range
0x0000 to 0x270F
(0 to 9999)
Setting of OUT1 set value
Unit specification (Unit):
When "L" is selected
2
R/W
AC1_L
(OUT1 index (L))
S16
0
Y
Setting range
0x0000 to 0x0008
(0 to 8)
Setting of OUT1 index value
Unit specification (Unit):
When "L" is selected
1310 0x051E
1
R/W
AC1_Ft
3
(OUT1 set value (Ft
3
))
S16
0
Y
Setting range
0x0000 to 0x270F
(0 to ¥9999)
Setting of OUT1 set value
Unit specification (Unit):
When "Ft
3
" is selected
2
R/W
AC1_Ft
3
(OUT1 index (Ft
3
))
S16
0
Y
Setting range
0x0000 to 0x0008
(0 to 8)
Setting of OUT1 index value
Unit specification (Unit):
When "Ft
3
" is selected
1500 0x05DC
1
R/W
OUT
2
a
c
cu
m
u
la
te
d
f
lo
w se
tt
in
g
AC2_L
(OUT2 set value (L))
S16
0
Y
Setting range
0x0000 to 0x270F
(0 to 9999)
Setting of OUT2 set value
Unit specification (Unit):
When "L" is selected
2
R/W
AC2_L
(OUT2 index (L))
S16
0
Y
Setting range
0x0000 to 0x0008
(0 to 8)
Setting of OUT2 index value
Unit specification (Unit):
When "L" is selected
1510 0x05E6
1
R/W
AC2_Ft
3
(OUT2 set value (Ft
3
))
S16
0
Y
Setting range
0x0000 to 0x270F
(0 to 9999)
Setting of OUT2 set value
Unit specification (Unit):
When "Ft
3
" is selected
2
R/W
AC2_Ft
3
(OUT2 index (Ft
3
))
S16
0
Y
Setting range
0x0000 to 0x0008
(0 to 8)
Setting of OUT2 index value
Unit specification (Unit):
When "Ft
3
" is selected