-77-
No.PF
※※
-OMX0002
●
Device detail status parameters (index 37)
Detailed event contents of readable device status are as follows.
Array
Event content
Event classification
Event code
Definition
Value
1
Internal failure of digital flow switch
Error
0xF4
0x8D02
2
Internal failure of digital flow switch
Error
0xF4
0x8D03
3
Internal failure of digital flow switch
Error
0xF4
0x8D04
4
Internal failure of digital flow switch
Error
0xF4
0x8D05
5
Internal failure of digital flow switch
Error
0xF4
0x8D01
6
Internal failure of digital flow switch
Error
0xF4
0x8D06
7
Internal failure of digital flow switch
Error
0xF4
0x8D08
8
Flow sensor error
Error
0xF4
0x8CD0
9
Temperature sensor error
Error
0xF4
0x8CD1
10
Outside the accumulated flow value measurement
warning
0xE4
0x8D80
11
Outside the instantaneous flow measurement
warning
0xE4
0x8C10
12
Test event A
warning
0xE4
0x8CA0
13
Test event B
warning
0xE4
0x8CA1
14
Data storage upload request
notification
0x54
0xFF91