-93-
No.PF
※※
-OMX0002
■
Characteristics data
●
Flow rate/ Analogue output
0 L/min
A
2
B
Voltage output
(1 to 5 V)
1
1 V
1.04 V
5 V
Current output
1
4 mA
4.16 mA
20 mA
0 L/min
C
2
D
Voltage output
(0 to 10 V)
1,
3
0 V
0.1 V
10 V
Models
Minimum value of rated flow range
*4
Maximum value of rated flow range
PF3A703H
30 L/min
3000 L/min
PF3A706H
60 L/min
6000 L/min
PF3A712H
120 L/min
12000 L/min
1: Analogue output accuracy is within ±3%F.S.
2: A and C change based on the setting of zero cut-off function.
3: Set the current to the analogue output from the connected equipment t
o 20 μA or less when selecting 0 to 10 V.
When 20
μA or more current flows, it is possible that the accuracy is not satisfied in the area at 0.5 V or lower.
4: The minimum value of the rated flow range changes based on the setting of zero cut-off function.