-65-
No.PF
※※
-OMX0002
■
[F99] Reset to the default settings
If the Flow switch settings are uncertain, the default values can be restored.
<Operation>
Display [F99] by pressing
▲
or
▼
button in function selection mode.
Press the S button.
Move on to reset to factory default settings.
Rest to factory default settings.
Press the
▲
or
▼
button to display [ON], then press S and
▼
buttons
simultaneously for 5 seconds or longer.
[F99] Reset to the default settings completed
All settings are returned to
the default values.
Return to function selection
mode.
[oFF] (not use) is selected
Press the S button to set.
Return to function selection
mode.