-89-
No.PF
※※
-OMX0002
■
Error display
Error name
Error display
Description
Measures
Instantaneous flow
error
Flow rate exceeding the upper limit
of the settable flow range is applied.
Reset applied flow rate to a level within
the settable flow range.
Over current error
The switch output load current is
80 mA or more.
Turn the power off and remove the
cause of the over current. Then supply
the power again.
System error
An internal data error has occurred.
Turn the power off and on again.
If the failure cannot be solved, contact
SMC.
to
Accumulated flow
error
The accumulated flow has exceeded
the accumulated flow range.
(For accumulated increment)
Reset the accumulated flow.
(Press the
▼
and S buttons
simultaneously for 1 second or longer)
The accumulated flow has reached
the set accumulated flow.
(For accumulated decrement)
Version does not
match
Version of master and IO-Link
does not match.
Align the master IO-Link version to the
device.
: If the error cannot be reset after the above measures are taken, or errors other than above are displayed, please contact SMC.