38
-
No.JXC
※
-OMU0030-A
5) Push set button (g) the 7-segment LED(f)
displays the
set value of the parameter without a dot.
If the value of the position switch (h) is changed at
this stage, it will return to the state of 4) above.
6) Press the set button (g) for 2 seconds or longer to
change the 7-segment LED(f) from on to flashing
state.
The set parameter value can be changed during this
state.
7) Push Forward button (i) or Reverse button (j) to
change the set value of the parameter ("3" is in this
example).
Keep pushing Set button (g) until the display of
7-segment LED (f) changes from flashing state to on
state (for 2 seconds or more).
When the display of
7-segment LED (f) is no-flashing state, the set value
is registered into the controller.
The changed parameter is applied after the power
supply for the controller is re-supplied.
The parameter setting is completed.
When set the other parameter, repeat the procedure of 4) to 7).
Caution
●
The changed parameter is applied after the power supply for the controller is re-supplied.
●
For the default value of the return to origin and the reference value of jog speed and inching
amount, refer to
“
10. Initial setting value of electric actuator (LEM series)”.
●
When the reference for rotating direction is changed, the direction of forward and reverse is
switched, and the speed and acceleration per direction are changed as well. Therefore, it is
necessary to set the position, speed and acceleration again.
(h)
(e)
(j)
(f)
(g)
(f)
(g)
(g)
(i)