31
-
No.JXC
※
-OMU0030-A
(7) Intermediate position setting
In the manual mode after return to origin, the position can be registered by the following 2 methods.
(A) Position setting by Jog operation and Inching operation.
Method to register the electric actuator slider position by Jog or Inching operation.
The following is an example of registering a position in
position number 3.
1) Switch Position switch (h) to the position number
to register ("3" is in this example).
7-segment LED (f) displays the position number.
The position can not be registered into the position
number "0",”1”,”2” and "F (15)".
2) When PWR LED (a) is ON, push Set button (g).
The electric actuator drives to the originally
registered position in the commanded position
number.
When completing, the display of 7-segment LED
(f) change from flashing state to solid light state.
Then, keep pushing Set button (g) until 7-segment
LED (f) displays with flashing.
The electric actuator stops on the way when Set button (g) is pushed during driving the electric
actuator.
Then, when Set button (g) is pushed again, the electric actuator drives to the originally registered
position.
Caution
●
When procedure
(2) Changes to Manual mode
is performed before the return to origin is not
completed, the driving command is canceled and the electric actuator does not drive.
In that
case,
perform the return to origin.
●
When the electric actuator cannot drive to the originally registered position due to the
mechanical interference, registers the position by (B) Direct teaching.
(f)
(h)
(f)
(g)
(a)
(b)
(h)