37
-
No.JXC
※
-OMU0030-A
2) Press and hold the Forward button (i) and Reverse
button (j) simultaneously for 3 seconds so that the
power supply LED (a) is changed from a solid light to
a flashing.
3) Set the value of the position switch (h) to "0" and
press and hold the set button (g) for 3 seconds. The
7-segment LED (f) displays "0" with a dot and the
alarm LED (b) flashes.
4) When the position switch (h) is set at the required
parameter number ("2" in this case), the 7-segment
LED (f) displays the value of the position switch (h)
with a dot.
No. Description
Function
1
Reference for
rotating direction
Changing forward and backward
direction
2
Jog speed level
Jog operation, speed setting during
inching operation
3
Inching level
Setting in moving distance during
inching operation
Refer to
“7.3 Setting parameters”
for the details of parameters.
(i)
(a)
(j)
(b)
(h)
(f)
(g)
(f)
(h)