18
-
No.JXC
※
-OMU0030-A
PLC, etc
(The PLC, etc. should be obtained separately.)
Controller input power supply 24 VDC
(The 24 VDC power supply and the power cable
should be obtained separately.)
4. External Wiring Diagram
Examples of standard wiring are shown for each connector (CN1 to CN4) of the controller.
4.1 CN1: Power supply cable
Controller
CN1 Power supply cable
Please refer to
“5. CN1: Power supply cable”
for how to wire the CN1 connector.
Caution
Do not use the inrush current suppression type power supply for the controller power (24VDC).
4.2 CN2: Motor power connector and CN3: Encoder connector
Connect the controller and the electric actuator with the actuator cable (LE-CP-
□
-
□
).
Controller
CN3 Actuator cable Electric actuator
CN2
4.3 CN4: Parallel I/O connector
Controller
I/O cable
CN4
Please refer to
"6.4 Parallel I/O Wiring Example"
for how to wire the CN4 connector.
Please refer to
"6.3 The parallel I/O signal is detailed"
for details of each signal of parallel I/O.
Motor