- 64 –
No.JXC
※
-OMY0002
(4) Return to origin cannot return while operating.
It cannot be done during positioning operation, pushing operation and pushing.
(5) Refer to a common auto switch /matter (Best Pneumatics No 2) when an auto switch is built in and
used.
(6) When conformity to UL is required, the electric actuator and controller should be used with a
UL1310 Class 2 power supply.
13.2 Mounting
Warning
(1) Install and operate the product only after reading the Operation Manual carefully and
understanding its contents. Keep the manual in a safe place future reference.
(2) Observe the tightening torque for screws.
Tighten the screws to the recommended torque for mounting the product.
(3) Do not make any alterations to this product.
Alterations made to this product may lead to a loss of durability and damage to the product, which can
lead to human injury and damage to other equipment and machinery.
(4) When using external guide, the guide axis should be parallel to the electric actuator axis.
There will be damage/excessive wear on the lead screw if the external guide is not parallel.
(5) When an external guide is used, connect the moving parts of the product and the load in such a
way that there is no interference at any point within the stroke.
Do not scratch or dent the sliding parts of the product tube or piston rod etc., by striking or grasping them
with other objects. Components are manufactured to precise tolerances, so that even a slight
deformation may cause faulty operation.
(6) Prevent the seizure of rotating parts.
Prevent the seizure of rotating parts (pins, etc.) by applying grease.
(7) Do not use the product until you verify that the equipment can be operated properly.
After mounting or repair, connect the power supply to the product and perform appropriate functional
inspections to check it is mounted properly.
(8) At the overhang mounted impeller fixation
There is a possibility that the power at the bending moment damages the electric actuator when moving it
at high speed.
The support metal fittings that suppress the vibration of the main body of the electric actuator are
installed.
Lower and use speed for the state that the electric actuator doesn't vibrate.
(9) When mounting the electric actuator or attaching to the
work piece, do not apply strong impact or
large moment.
If an external force over the allowable moment is applied, it may cause looseness in the guide unit, an
increase in sliding resistance or other problems.
(10) Maintenance space.
Allow sufficient space for maintenance and inspection.