12. Wiring of cables/Common precautions
Warning
(1) Adjusting, mounting or wiring change should never be done before shutting off the power supply
to the product.
Electrical shock, malfunction and damag can result.
(2) Never disassemble the cable. Use only specified cables.
(3) Do not remove or connect the cable and connector while power is supplied.
Cution
(1) Wire the connector securely. Do not apply any voltage to the terminals other than those specified
in the product Manual.
(2) Wire the connector securely.
Check for correct connector wiring and polarity.
(3) Take appropriate measures against noise.
Noise in a signal line may cause malfunction. As a countermeasure, separate high voltage and low
voltage cables, and shorten wiring lengths, etc.
(4) Do not route wires and cables together with power or high voltage cables.
The product can malfunction due to interference of noise and surge voltage from power and high voltage
cables to the signal line. Route the wires of the product separately from power or high voltage cables.
(5) Take care that electric actuator movement does not catch cables.
(6) Operate with cables secured. Avoid bending cables at sharp angles where they enter the product.
(7) Avoid twisting, folding, rotating or applying an external force to the cable.
Risk of electric shock, wire break, contact failure and loss of control for the product
can happen.
(8) Fix the motor cable protruding from the product in place before using.
The motor and lock cables are not robotic type cables and can be damaged when moved. Therefore, do
not place A part below it in a flexible moving tube
.
(9) Select "Robotic type cables" in case of inflecting the electric actuator-cable repeatedly. And do
not put cables into a flexible moving tube with a radius smaller than the specified value. (Min.
50mm).
Risk of electric shock, wire break, contact failure and loss of control for
the product
can happen if "Standard cables" are used in case of inflecting
the cables repeatedly.
(10) Confirm proper wiring of the product.
Poor insulation (interference with other circuits, poor insulation between
terminals and etc.) can apply excessive voltage or current to the product causing damage.
(11) The Speed / pushing force may vary, depending on the cable length, load and mounting
conditions etc.
If the cable length exceeds 5m, the speed / pushing force will be reduced by a maximum of 10% per
5m. (If cable length is 15m: Maximum 20% reduction.)
[Transportation]
Cution
(1) Do not carry or swing the product by the motor or the cable
Motor cable
A
Connector
Actuator cable
Robotic type cable (Flexible type cable)