- 37 –
No.JXC
※
-OMY0002
7. Setting Data Entry
In order to move the electric actuator to a specific position, it is necessary to setup the patterns of
operations with the controller setting software or the teaching box. This setup data input by the controller
setting software or teaching box will be recorded in the memory of the controller.
For the controller setting software and the teaching box, there are two available modes. The appropriate
mode can be selected depending on the purpose.
●
Easy mode
In Easy mode, the electric actuator can be started by entering only a limited number of settings with the
controller setting software and the teaching box.
The combination of settings you need to set up will change depending on the type of the electric actuator.
(combination of data can be selected.)
●
Normal mode
In Normal mode, a more detailed setup can be made (conditions for the electric actuator and controller,
etc.) than in Easy mode.
You can change three kinds of setting data, "Step data", "Basic parameter" and "Return to origin
parameter" in this mode.
7.1 Step data
Step data is the actual data relating to the operation of the electric actuator.
There are 64 patterns of step data. Each of them has 12 item to be set.
Each step data will become effective as soon as it is written to the controller.
Example) Step data of the control1ler setting software [Normal mode]
No.
Move
Speed
mm/s
Position
mm
Accel
mm/s
2
Decel
mm/s
2
PushingF
%
TriggerLV
%
PushingSp
mm/s
Moving F
%
Area1
mm
Area2
mm
In posn
mm
0
ABS
100
20.00
1000
1000
0
0
0
100
18.00
22.50
0.5
1
ABS
50
10.00
1000
1000
70
60
5
100
6.0
12.0
1.5
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
63
ABS
20
5.00
500
500
0
0
0
100
3.0
8.0
1.2
Caution
Writing of the step data should be performed while the electric actuator is stopped.