- 58 –
No.JXC
※
-OMY0002
Controller Setup
Software
(code)
Teaching
box name
G
rou
p
How to
deactivate
Alarm contents/ Countermeasure
The motor
speed has
exceeded the
set value
(01-144)
Over
speed
D
RESET
SVON
Input
<Contents>
The motor speed exceeds a specific level due to an external
force, etc.
<Countermeasure>
Make improvements such that the motor speed will not
exceed the maximum speed of the electric actuator.
Caution
Please refer to the manual or the catalogue of the
electric actuator for the maximum speed of the electric
actuator.
The power
supply voltage is
not within the
specification.
(01-145)
Motor
error
D
RESET
SVON
Input
<Contents>
The motor power supply voltage is out of range. During
[SVON].
<Countermeasure>
Make sure that the voltage supplied to the motor power
(M24V) of the controller is within specification.
Caution
If the power supply is "inrush current control type", a
voltage drop may cause an alarm during acceleration/
deceleration.
<Contents>
The alarm may be increased by regenerative power depending
on the method of operation of the electric actuator.
<Countermeasure>
Make sure that the operating conditions are within the
specifications.
Caution
Please refer to the manual or the catalogue of the
electric actuator for the method of operation of the
electric actuator.
The Controller
temperature has
exceeded the
specification
(01-146)
Over
Temp.
D
RESET
SVON
Input
<Contents>
The temperature around the power element of the controller
is too high.
<Countermeasure>
Make improvements so that the temperature around the
controller is kept appropriate.