- 27 -
Recommended Parameter Values [LEY]
Series
LEY25/
LEYG25
LEY25D/
LEYG25D
LEY32/
LEYG32
LEY32D/
LEYG32D
Lead symbol
A
B
C
A
B
C
A
B
C
A
B
C
Lead
12
6
3
12
6
3
20
10
5
16
8
4
Parameter
*1,*2
Para. No
Initial
value
Recommended value
Number of command
input pulses per
revolution *3
PA05
0
0
Electronic gear
numerator *3
PA06
1
32768
65536
32768
65536
32768
65536
32768
Electronic gear
denominator *3
PA07
1
150
75
75
150
75
75
250
125
125
200
100
50
Regenerative option
PA02
0000
0000 (Non)/ 0002 (LEC-MR-RB-032)
Rotation direction
selection
*4
PA14
0
0
(+
:
Counter
motors side)
1
(+
:
Counter
motors side )
0
(+
:
Counter
motors side)
1
(+
:
Counter
motors side )
Adaptive tuning mode
PB01
0000
0000
Load to motor inertia
moment ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape selection
1
PB14
0000
0000
Series
LEY63
LEY63D
Lead
A
B
C
L
A
B
C
Equivalent Lead
(Including pulley
ratio)
20
10
5
5(2.86)
(Pulley
ratio 4/7)
20
10
5
Parameter
*1,*2
Para. No
Initial value
Recommended value
Number of
command input
pulses per revolution
*3
PA05
0
0
Electronic gear
numerator *3
PA06
1
32768
65536
114688
32768
65536
Electronic gear
denominator *3
PA07
1
250
125
125
125
250
125
125
Regenerative option
PA02
0000
0000 (Non)/ 0002 (LEC-MR-RB-032)/ 0003 (LEC-MR-RB-12)
Rotation direction
selection
*4
PA14
0
0
(+
:
Counter motors side)
1
(+
:
Counter motors side )
Adaptive tuning
mode
PB01
0000
0000
Load to motor inertia
moment ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape
selection 1
PB14
0000
0000
Different from the initial value.
*1 Parameter is the recommended value. Please change the parameter to make appropriate value for your operating method.
*2 A mechanical resonance may occur depending on the configuration or the mounting orientation of the transferred object. Please
change the parameter in the initial setting.
(Parameter initial configuration
⇒
Set the recommended parameter value
⇒
Operation start)
*3 The travel distance of the actuator per 1 pulse should be 10 [μm/pulse].
*4 When the motor mounting position is on the right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L /
LEYG*L), the rotation direction selection is 0(+: Counter motors side).