- 22 -
5.3.1 Change of parameter block
To enable settings for all parameters.
①
Select “Basic” tab and change “PA19” value to “000C”.
②
Click the “PA19” row then click “Selected Items Write”.
③
Cycle the power for parameters for this driver to be enabled.
④
Please click “Read".
When changing of each parameter, note the following points.
Note1) For various parameters, there is "Enable once by cycling the power after setting". (If you do not cycle the
power, it does not register the data in the driver.)
Note2)
“Selected Items Write”: It writes the specific parameter values of the corresponding frame to the driver.
“Single Axis Write”: It writes all of the parameters to the driver.
Note3) Do not change
“For manufacturer setting” parameters.
If you change by these by mistake, it may cause
the amplifier to not work properly.
5.3.2 Read of parameters
If you read the parameters of the driver to the software, please perform a
“read” operation.
①
From the View menu bar "parameter (A)" - please click on the "parameter setting (P)". "Parameter Settings"
screen will display.
②
Please click on the “Read".
④
②
②
①