- 45 -
5.6.1 Positioning Mode
①
In order to prevent accidental impact at the end of the stroke, operate the actuator at a low speed
initially. When changing speed or movement, increase the values whilst checking operation (Change
motor speed, acceleration/deceleration time, movement distance values if required).
See
“LECSB Operation Manual (Simplified Edition)”,section 5.6.2 for motor speed configuration.
See “LECSB Operation Manual (Simplified Edition)”, section 5.6.3 for acceleration/deceleration time
configuration.
See
“LECSB Operation Manual (Simplified Edition)”, section 5.6.4 for movement distance
configuration.
Actuator positioning operates using [Forward (CCW)] and [Reverse (CW)].
(Check wiring and parameters if operation cannot be performed correctly)
When performing JOG operation in the setup software, the rotation direction of the actuator does not change
if you change the setting of parameter PA14 (Rotation direction selection).
The actuator moves in the
direction of [Forward (CCW)] button and [Reverse (CW)] button.
②
Check the command impulse unit (electronic gear enabled).
The electronic gear duty set to PA05/PA06/PA07 will be enabled.
See
“LECSB Operation Manual (Simplified Edition)”, section 5.3.4 – “Parameter Values by Actuator Model”
for PA05/PA06/PA07 settings for each actuator.
If PA05/
PA06/PA07 are set to the values in “LECSB Operation Manual (Simplified Edition)”, section 5.3.4–
Parameter Values by Actuator Model, the travel distance of the actuator per 1 pulse will be calculated as
follows.
・
travel distance of the actuator per 1 pulse
=
10
[μ
m
] ( 0.01[mm])
③
If the “Stroke-end” (LSP, LSN) signal is not configured as ON, an alarm may occur. (When
checked, the “stroke-end” (LSP, LSN) will be automatically turned ON only when this window is
open.)
Item
Setting range
Unit
Description
Motorspeed
0 ~ Allowed Speed for
each actuator
r/min
Set the command speed of the servo motor for execution of positioning
(
Motor rotations/min
).
Acceleration/de
celeration time
0 ~ 50000
ms
Set the time until the servo motor reaches/slows to the rated speed
(3000 r/min)
Move distance
0 ~ 2147483647
pulse
Sets movement distance.
①
②
③
④