- 32 -
(1) Set the input configuration of the LECSB pulse train input signal.
Set parameter: [PA13]
Parameter
Initial
value
Unit
Setting
range
Control mode
No.
Symbol
Name
Position Speed
Torque
PA13
PLSS
Command pulse input form
0000h
Refer to
the text.
Select the input form of the pulse train input signal. Command pulses may be input in any of three different forms, for
which positive or negative logic can be chosen.
Arrow
or
in the table indicates the timing of importing a pulse train.
A- and B-phase pulse trains are imported after they have been multiplied by 4.
Selection of command pulse input form
Setting
Pulse train form
Forward rotation command
Reverse rotation command
0010h
N
e
g
a
tiv
e
log
ic
Forward rotation pulse train
Reverse rotation pulse train
NP
PP
0011h
Signed pulse train
PP
L
H
NP
0012h
A-phase pulse train
B-phase pulse train
PP
NP
0000h
P
o
s
it
iv
e
log
ic
Forward rotation pulse train
Reverse rotation pulse train
NP
PP
0001h
Signed pulse train
L
H
PP
NP
0002h
A-phase pulse train
B-phase pulse train
PP
NP
EX.) To set the command pulse input configuration to pulse train + Symbol in a positive logic.
[PA13] = 0001
①
Set the "PA13" to "0001"
in the "Basic" tab.
②
Click on the "Single Axis Write" button.
③
Turn the power OFF and ON again. Parameter is enabled.