- 17 -
4.4 Torque control mode
(1)
[Extension setting parameters (No. PC□□)]
No.
Symbol
Name
Initial value
Unit
PC01
STA
Acceleration time constant
0
ms
PC02
STB
Deceleration time constant
0
ms
PC05
SC1
Internal speed limit 1
100
r/min
PC06
SC2
Internal speed limit 2
500
r/min
PC07
SC3
Internal speed limit 3
1000
r/min
PC08
SC4
Internal speed limit 4
200
r/min
PC09
SC5
Internal speed limit 5
300
r/min
PC10
SC6
Internal speed limit 6
500
r/min
PC11
SC7
Internal speed limit 7
800
r/min
5. Parameter Configuration using Setup software (MR Configurator2
TM
)
This section describes the configuration procedure for main parameters using the setup software (MR
Configurator2
TM
: LEC-MRC2E). See chapter 5
of the “LECSB Operation Manual” for parameter details.
5.1 Setup software (MR Configurator2
TM
)
*1 Setup software version 1.19V or above is required.
*2 The setup software (MR Configurator2
TM
: LEC-MRC2E) must be purchased as an additional item.
*3 The USB cable (LEC-MR-J3USB) must be purchased as an additional item.
5.1.1 Installation Method
Perform installation according to the “MR Configurator2
TM
instruction manual
” (Manual/ib0300160*.pdf) contained on
the setup software (MR Configurator2
TM
) CD-ROM. The
“MR Configurator2
TM
” software will be added to the PC.
5.2 Basic driver set-up for Initial Test Drive
Switch on the
main circuit power supply (AC100V/AC200V) and controller circuit power supply
(AC100V/AC200V) to the LECSB driver.
When the driver display flashes as shown below,
it wires for EMG (Emergency stop) and ON (state of EMG
release (operational)). However, EMG (Emergency stop) cannot be compulsorily set to automatic ON by
the parameter.
If you turn on the power supply for the first time, refer to "LECSB
Operation Manual”, chapter 4.