- 65 -
Refer to “LECSB Operation Manual”, section 5.4 for assignment of signal.
LECSB speed command parameter setting
(Note) Input device
Speed command value
SP3
SP2
SP1
0
0
0
Analog speed command (VC)
Initial
phase
0
0
1
Internal speed command 1 (parameter No.PC05)
0
1
0
Internal speed command 2 (parameter No.PC06)
0
1
1
Internal speed command 3 (parameter No.PC07)
1
0
0
Internal speed command 4 (parameter No.PC08)
1
0
1
Internal speed command 5 (parameter No.PC09)
1
1
0
Internal speed command 6 (parameter No.PC10)
1
1
1
Internal speed command 7 (parameter No.PC11)
Note. 0: off
1: on
For LECSB, analog speed command and speed from 7 patters can be set.
Signals assigned at the initial setting are SP1 and SP2.
Assign signals of speed selection 3 (SP3) when the driver is used to [Internal speed command 7].