The GSM/GPRS module housing can be mounted on the lower half of the pole. If supplied, the
GSM/GPRS solar power supply can also be mounted opposite it.
The raingauge is ground mounted and the soil temperature inserted into the soil.
A barometer can be mounted just above halfway up the pole, its orientation is not critical.
The light or solar radiation sensor on its long arm pole mount can be mounted so that the top of the
sensor is approximately at the height of the top of the pole, and orientated North or South as
appropriate.
The DataHog or MiniMet incorporating the RH and air temperature probes are usually placed
opposite the light sensor, to counter each other's weight. The short arm pole mount on the logger
means that it is possible to place the top of the radiation screen also at the height of the top of the
pole.
If the RH and air temperature sensors are separate from the datalogger, mount this on its long arm
bracket lower than the light sensor, to ensure that it does not obscure any sunlight from the sensor.
Finally, the wind sensor(s) are placed over the top of the pole using the pole cap mount.
Run cables up and down the pole as necessary, using gaps between the pole and the 'V' bolts,
cable ties and the supplied adhesive cable tidy to secure cables
34
MiniMet Installation
Содержание MiniMet
Страница 1: ...MiniMet Installation Manual Iss 2 0...
Страница 45: ...APPENDIX 2 CONCRETE BASE FOR A 2M MAST 44 MiniMet Installation...
Страница 46: ...APPENDIX 3 SITE LOCATION 45 MiniMet Installation...
Страница 47: ...APPENDIX 4 ASSEMBLY OF MAST SUPPLIED IN MORE THAN ONE SECTION 46 MiniMet Installation...
Страница 49: ...APPENDIX 6 RAINGAUGE BASEPLATE 48 MiniMet Installation...
Страница 50: ...APPENDIX 7 MOUNTING OF GSM GPRS ENCLOSURE TO BRACKET 49 MiniMet Installation...
Страница 51: ...APPENDIX 8 MOUNTING THE GSM GPRS MODULE ON THE MAST NO SOLAR PANEL 50 MiniMet Installation...
Страница 52: ...APPENDIX 9 MOUNTING OF THE GSM GPRS UNIT ON THE MAST WITH A SOLAR PANEL STEP 1 51 MiniMet Installation...
Страница 53: ...APPENDIX 10 MOUNTING OF THE GSM GPRS UNIT ON THE MAST WITH A SOLAR PANEL STEP 2 52 MiniMet Installation...
Страница 54: ...APPENDIX 11 MOUNTING OF GSM GPRS UNIT ON THE MAST WITH A SOLAR PANEL STEP 3 53 MiniMet Installation...
Страница 55: ...APPENDIX 12 TYPICAL MINIMET INSTALLATION WITH GSM GPRS 54 MiniMet Installation...
Страница 56: ...APPENDIX 13 TYPICAL MINIMET INSTALLATION WITHOUT GSM GPRS 55 MiniMet Installation...
Страница 57: ...APPENDIX 14 56 MiniMet Installation...
Страница 58: ...APPENDIX 15 FITTING THE BATTERY COVER 57 MiniMet Installation...