54
Replacement Procedures
Service Manual
SKOPE TME-N ActiveCore
Ambient Probe
The ambient probe is located above the door. It monitors the temperature
around the refrigeration unit.
Note:
The ambient probe is wired in series with
the door switch.
To replace the ambient probe
Ambient probe
1. Disconnect the chiller from the power supply (see page 30).
2. Remove the sign panel.
3. Detach the refrigeration
unit and carefully push
back or remove to allow
access to the cabinet
electrics cover.
4. Unscrew the cabinet electrics cover.
5. Detach the probe from the electrics cover, and trace the probe cable back to
the connector, cutting cable ties as required, and unplug.
6. Fit the new probe and secure with cable ties. Ensure the probe is located in
the same location as the original probe (as pictured above).
7. Reassemble the unit and test for correct operation.
Cabinet electrics cover