32
Replacement Procedures
Service Manual
SKOPE TME-N ActiveCore
To replace the LED driver power supply
To replace an interior wiring loom
1. Disconnect the chiller from the power supply.
2. Remove the sign panel.
3. Detach the refrigeration
unit and carefully push
back or remove to allow
access to the cabinet
electrics cover.
4. Unscrew the cabinet electrics cover.
5. Remove the light power
supply.
6. Replace the light power supply and reassemble.
1. Disconnect the chiller from the power supply.
2. Unplug the light from the wire loom.
3. Gain access to the cabinet electrics panel (see procedure above).
4. Move up to the cabinet roof, and unplug the wiring loom from the light power
supply, and if applicable the sign light.
5. Remove the putty from the loom entry point on the cabinet roof, and pull the
loom up through the cabinet ceiling.
6. Refit the new loom and reassemble. Ensure:
All plugs are clean, correctly fitted and plugged in.
That the ceiling and roof hole is completely sealed with putty.
Cabinet electrics cover
Light power supply