51
SKOPE TME-N ActiveCore
Replacement Procedures
Service Manual
Door Switch
The chiller is fitted with a door switch above each door, which tells the
electronic controller when a door is opened. A small magnet in the door
frame activates the switch. A cable connects the switch to the electronic
controller via an inline connector on top of the cabinet.
To remove the door switch
Control Probe
The control probe is cable tied to a bracket on the evaporator fan motor
bracket (see image below).
To replace the control probe
1. Disconnect the chiller from the power supply.
2. Disconnect the door switch cable plug from the inline connector on top of
the cabinet.
3. Unscrew the two fixing screws from the door switch and remove.
4. Fit the replacement door switch and connect via the inline connector.
1. Remove the evaporator fan assembly (see page 46).
2. Detach the probe from the evaporator fan shroud bracket and trace the
probe cable back to the unit electrics box and unplug (see page 42).
3. Following the same path as the original probe, fit the new probe with cable
ties as necessary. Ensure the probe cable is securely plugged into the rear
of the unit junction box, and that it is cable tied to the evaporator fan shroud
bracket, with the probe bent away from the fan bracket at a 45° angle.