31
SKOPE TME-N ActiveCore
Replacement Procedures
Service Manual
Lighting fault diagnostics
To replace an interior light component
Problem
Possible Cause
Repair
No lights working.
Cabinet is dark.
Lights switched off.
Switch lights on at
electronic controller
faceplate (see page 9), or
the app.
Controller is in Energy
Saving mode.
Open the door to bring
the controller into Normal
mode.
Controller alarm.
Check controller for alarm
code.
Plug not connected
properly.
Check and clean plugs on
top of the cabinet.
Light power supply fault.
Replace light power
supply.
Light component not
working.
Plug not connected
properly.
Check and clean plug
connection in side light
channel, behind the loom
cover.
Faulty light.
Replace light.
Segment of light not
working.
Faulty light.
Replace light.
1. Unplug the chiller from the power supply.
2. Unplug the light, and
remove the light from the
plastic casing.
3. Clip the replacement
light into place on the
plastic casing, ensuring
the male end of the light
is at the top, and plug the
light in.
4. Ensure the light is firmly and completely clipped in.
5. Reconnect to the power supply and check for correct operation.