35
SKOPE TME-N ActiveCore
Replacement Procedures
Service Manual
To replace the top hinge bracket (if necessary)
To refit the door
4. Remove the split pin from
the capstan at the bottom
hinge (outside door
pictured).
5. Unscrew and remove the
tension bracket. Take care
when removing as the
bracket is under tension.
6. Unscrew the top hinge, and lift the door up and off the cabinet.
1. Follow the steps on the previous page to remove the door.
2. Remove the top hinge from the top of the door and replace.
1. Lift the door onto the bottom hinge.
2. Fit the top hinge to the top of the door, and partially fix in place on the top of the
cabinet. Align the door with the cabinet and tighten the fixing screws.
Ensure the top hinge spacer is fitted under the top hinge before fixing the top
hinge in place.
3. Apply tension to the door
(see page 36).
4. Fit the split pin through the
hole in the capstan to lock
the door in place (outside
door pictured).
5. Fit the height adjustment
block to the bottom screw
hole (not fitted to middle
doors). As standard, the
notched edges on the
bottom of the hinge and the
top of the height adjustment
block align to set the door to
the correct level. If
necessary, rotate the height
adjustment block to level the
door.
Split pin
Bottom
hinge
Capstan
Tension
bracket
Split pin
Bottom hinge
Capstan