44
Replacement Procedures
Service Manual
SKOPE TME-N ActiveCore
Unit Cover
Remove the unit cover to access parts within the unit assembly.
To remove the unit cover
Condenser
Fan
The condenser fan assembly is made up of a fan motor, fan blade and
mounting brackets which can be replaced if necessary.
If the fan stops for any reason, check all connections to ensure no plugs
have come loose. Refer to the label on the electrics box cover to identify the
condenser fan plug and socket in the electrics box.
ActiveCore R290 Junction Box Layout
1
4
5
8
9
13
14
15
16
18
20
7
10
11
12
6
19
17
2
3
Key Colour Description
Key Colour Description
1
n.a.
Not used
11
n.a.
Not used
2
White Controller Signal
12
n.a.
Not used
3
Blue
Controller Return
13
n.a.
Not used
4
Black Trace Heating
14
n.a.
Not used
5
White Lighting
15
Blue
Compressor
6
Red
Controller Power
16
Black
Evaporator Sensor
7
White Door Sensor
17
Blue
Appliance Sensor
8
n.a.
Not used
18
Red
Condenser Fan
9
n.a.
Not used
19
White
Evaporator Fan
10
n.a.
Not used
20
Red
Condenser Sensor
/
$%
5HY
-XO\
1. Disconnect the chiller from the power supply and remove the refrigeration
unit (see page 41).
2. Unscrew the four machine
screws from the sides of
the refrigeration unit and
lift the cover off the unit.
IMPORTANT
Replace the motor with the same SKOPE OEM part.
DO NOT use alternative parts.