406388/B
31
Procedure
1
Do the following preparations.
a
Turn on the Processor Unit.
b
Verify that you have administrative rights.
c
Switch off any firewall applications.
d
Open the operating systems’s
Network and Sharing Center
, and set the IP address
for the network adapter used to communicate with the transceiver.
•
IP Address
: 192.168.1.30
•
Subnet mask
: 255.255.255.0
2
Install the TV80 operational software.
3
On the
Software License
page, install the software license(s).
4
Connect the Receiver Unit to the Processor Unit.
5
Set up the SR70 Receiver Unit / SR15 Receiver Unit in the TV80 application.
6
Set up the PI50/PI60 Receiver Unit in the TV80 application.
7
Select the gear you wish to use.
8
Select one or more catch monitoring sensors, and place them on the chosen gear.
9
Open the
Receiver
dialog box to define the parameters related to reception, such as
filter and gain.
10
Open the
Measurements
dialog box to verify that each sensor provides the expected
information.