Cable layout and connections
71
851-164574 / C
2
Set the mains voltage selector switch
S201
on the Power
Supply and
S203
on the HV Power Unit to correspond to the
correct mains voltage (115 Vac or 230 Vac).
3
Set the service switch
S202
on the Power Supply to the
Off
(middle) position.
4
Connect the mains power cable to a normal mains outlet in
the sonar room.
- If the delivered cable connector does not fit use an
adaptor, or replace with a suitable plug.
→
For connection of the mains cable, refer to figure 22 on page 66.
C16 - Transducer cable
The transducer cables are provided by the manufacturer. They are
physically connected to the top of the transducer shaft.
Caution
Do not mount the flexible transducer cable to the Transceiver
Unit.