Simrad SP60
94
851-164574 / C
2
Measure the three-phase voltage on the terminals of the
motor overload switch
S301
in the motor control unit.
- Write down the measured voltage here:
Supply voltage (Vac):
WARNING
The mains voltage is lethal. Observe the safety
precautions described in the general safety
rules.
→
Refer to page 9.
Re-wire for 230 Vac 3-phase
The hoist/lower motor is normally pre-wired for 380 / 440 Vac
three-phase. If the measured three-phase voltage is 230 Vac, the
motor must be rewired.
1
Remove the 3-phase mains fuses for the hull unit in the ship’s
fusebox.
2
Remove the cover for the mains connection to the motor.
→
Refer to figure 33 on page 94.
3
Rearrange the motor connections so that they correspond to
the measured voltage.
Figure 33 Mains
connection to the
motor
230 Vac
380 / 440 Vac
4
Adjust the release current on the motor overload switch
S301
according to the three-phase voltage:
•
230 Vac:
5.5 A
•
380 / 440 Vac : 4 A (minimum)