7.5 Sonar room cabling
Introduction
All sonar room cabling must be performed as specified. The cable
numbers used to identify the cables in the figures and following
procedures are identical to those used in the cable plan and cable
overview table.
(C
D
5
700A
)
C17
C15
C18
Live Neutral
Ground
Figure 22
Transceiver Unit cable
connections
Note
Due to the flexible shock mounting, all cables connected to the
Transceiver Unit must have appropriate slack to allow for
approximately 10 cm cabinet movement in all directions.
Cables
C17 - Motor control
This cable is connected between the Transceiver Unit and the
Motor Control Unit mounted on the Hull Unit. Use the surplus of
cable C15, or an equivalent type of cable.
→
Refer to page 180 for detailed information about the cable and the
connections to be made.
Observe the following procedure. To ensure correct operation, tick
off every item when the action has been carried out.
1
Use the cable gland on the left-hand side of the Transceiver
Unit.
→
The bottom of the Transceiver Unit is shown in figure 22.