Start-up procedures
89
851-164574 / C
9.3 Starting up the stand-by power supply
In order to start up the sonar units, the +24 Vdc stand-by power
supply in the Transceiver Unit must be started first.
Figure 30 The Transceiver Unit
power system
Observe the following procedure to start up the stand-by power
supply. To ensure correct operation, tick off every item when the
action has been carried out.
1
Check that the mains input connector
P201
on the front of
the power supply in the Transceiver Unit is disconnected.
→
Refer to figure 30.
2
Check that the switch
S202
on the front of the power supply
is set in the
Off
(middle) position.
3
Insert the mains fuses for the Transceiver Unit on the ship’s
mains fuse box.